<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Recent posts to news</title><link href="https://sourceforge.net/p/electricdss/news/" rel="alternate"/><link href="https://sourceforge.net/p/electricdss/news/feed.atom" rel="self"/><id>https://sourceforge.net/p/electricdss/news/</id><updated>2026-01-30T14:08:06.659000Z</updated><subtitle>Recent posts to news</subtitle><entry><title>OpenDSS Version 11.0.0.1 - Charlottesville - Released</title><link href="https://sourceforge.net/p/electricdss/news/2026/01/opendss-version-11001---charlottesville---released/" rel="alternate"/><published>2026-01-30T14:08:06.659000Z</published><updated>2026-01-30T14:08:06.659000Z</updated><author><name>EPRI</name><uri>https://sourceforge.net/u/epri/</uri></author><id>https://sourceforge.netea143d6459af1914606bb759cc825b55ec42913f</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;We are pleased to announce the release of OpenDSS Version 11.0.0.1 - Charlottesville.&lt;/p&gt;
&lt;p&gt;This version is named in honor of the birthplace of Tom McDermott, who, together with Roger Dugan, has played a foundational role in building and advancing OpenDSS since its inception.&lt;/p&gt;
&lt;p&gt;This release includes significant enhancements to switching and protection control elements (swtcontrol, fuse, recloser, and relay) to support improved modeling of unganged devices. It also expands the capabilities of the regcontrol element to better handle transitions between forward and reverse modes.&lt;/p&gt;
&lt;p&gt;On the DSS scripting side, the batchedit command has been enhanced and now supports conditional filters for selecting the objects of a given class that will be edited.&lt;/p&gt;
&lt;p&gt;Additional fixes and improvements have been applied across several components, including storagecontroller, invcontrol, memory mapping, and overload reporting, among others.&lt;/p&gt;
&lt;p&gt;A complete list of changes is provided in the README file included with the distribution.&lt;/p&gt;
&lt;p&gt;As always, if you have any questions, please use the SourceForge discussions, and the OpenDSS team will respond as availability permits.&lt;/p&gt;
&lt;p&gt;The OpenDSS Team   &lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>2022 Virtual Training</title><link href="https://sourceforge.net/p/electricdss/news/2022/08/2022-virtual-training/" rel="alternate"/><published>2022-08-03T15:25:10.220000Z</published><updated>2022-08-03T15:25:10.220000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.netf1950d24567a3a13abeddf5d30281724ffbedbc0</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;EPRI is planning another 4-day virtual training course this year.  See the attachment for more information and registration link.&lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>Voltage Base Rules</title><link href="https://sourceforge.net/p/electricdss/news/2020/10/voltage-base-rules/" rel="alternate"/><published>2020-10-06T14:24:07.118000Z</published><updated>2020-10-06T14:24:07.118000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.net1cf53562b8d88ee0025cc0360a95049a2c771fbe</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;With several new users since the global training in August, it is useful to review the OpenDSS voltage base rules since they are different than many other programs:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Voltage bases are not used for the solution of the network; the per-unit system is not used internally. The solution is performed in actual volts, amps, and ohms (or siemens) .&lt;/li&gt;
&lt;li&gt;There must be sufficient data provided for each circuit element of the system model to formulate the model of the element in actual impedance values. So the kV value is used as a base to convert input values in pu, percent, or power to ohms.&lt;/li&gt;
&lt;li&gt;Since most power engineers refer to ratings of 3-phase system elements as L-L kV, OpenDSS uses L-L kV for the ratings of 3-phase elements.&lt;/li&gt;
&lt;li&gt;We extended that rule to include elements that are declared as 2-phase, since in the US, most 2-phase systems are 2 phases of a 3-phase system with the voltages related by sqrt(3) and displaced 120 degrees from each other. (You can do that if you have a neutral conductor).&lt;/li&gt;
&lt;li&gt;The kV rating of 1-phase devices is the value that appears across the two wires of each terminal at 100% rated voltage. This would apply to all Power Conversion (PC) elements and Transformer elements. Note that 1-phase LINE elements have only one conductor per terminal; LINE elements are defined in ohms and do not have a voltage base. They can be connected anywhere in the circuit without concern for matching voltage bases. (In this regard, OpenDSS is formulated more like an EMT program than the usual power flow.)&lt;/li&gt;
&lt;li&gt;OpenDSS can model high phase order systems (e.g., 6-phase). The kV value is generally L-L rating for these systems. However, I would recommend running a small test with a few elements that you can verify the solution by inspection to see if OpenDSS interepreted the model correctly. (We have tested both 6-phase and 12-phase models.)&lt;/li&gt;
&lt;/ul&gt;&lt;/div&gt;</summary></entry><entry><title>Confusion due to IEEE Transactions Paper</title><link href="https://sourceforge.net/p/electricdss/news/2019/07/confusion-due-to-ieee-transactions-paper/" rel="alternate"/><published>2019-07-31T02:56:33.375000Z</published><updated>2019-07-31T02:56:33.375000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.net4525e79ae06cf7eb9e4ef6fa771d85e43da32802</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;Some users have noticed the paper on an open-source Python-based power flow tool called "pandapower" published in the IEEE Transactions on Power Systems November 2018 issue. Some comments were made in the paper about OpenDSS that mischaracterize the program and that has raised some concern among the users. Using the comparisons in the IEEE paper, it is time to revisit some of the unique features of OpenDSS for newer users.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;
&lt;p&gt;Delphi now compiles programs for &lt;strong&gt;Linux&lt;/strong&gt;. The capability comes with the Enterprise version. The Free Pascal Compiler (FPC/Lazarus) has had this capability for a longer time and Tom McDermott has been supporting a Linux version on Sourceforge for some time. I believe an Apple version is also available.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;In a commercial environment, Delphi is not free like Python, but students and other individuals can obtains a&lt;strong&gt; free version of Delph&lt;/strong&gt;i for the Windows environment that is fully capable of compiling OpenDSS.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;Many users prefer to work with OpenDSS through Python. This gives the users easy access to the numerous features available in Python while also accessing the speed and power from the natively-compiled OpenDSS program. There are multiple versions of Python interfaces developed by various third parties and made available either through Github or Sourceforge.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;&lt;strong&gt;Version 8 has parallelization built in&lt;/strong&gt;. It can perform long QSTS simulations exploiting temporaral parallelization.  It also has support for Davis Montenegro's A-Diakoptics techniques in which large circuits are torn into several small ones for parallel solution. These features were developed by EPRI with support from Sandia National Labs and NREL.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;&lt;strong&gt;OpenDSS-G&lt;/strong&gt;, released in 2018, and based on Version 8, also provides a graphical user interface.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;OpenDSS circuit models are not limited to only 3 phases. The line in the IEEE NEV Test Feeder has 17 coupled conductors in the first pole span. And that is not the limit. In fact there is not a limit on the number of conductors. &lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;OpenDSS has the typical 2-winding and 3-winding &lt;strong&gt;transformer model&lt;/strong&gt;s used in power system analysis, but there is actually no limit to how many windings a transformer may have. 4-winding transformers are common. Special simulations with more than 40 windings have been performed. The key is obtaining the short circuit impedances between each pair of windings. Single-phase transformers may be combined to create nearly any winding configuration imagineable. The &lt;strong&gt;AutoTransformer&lt;/strong&gt; element was introduced in 2019 in support of the  GIC harmonics analysis.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;Studies of &lt;strong&gt;higher-phase-order&lt;/strong&gt; systems with 6-phase sources, lines, transformers, and reactors have been conducted. Not sure what the limit is, if any.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;OpenDSS has been able to model &lt;strong&gt;ideal switches&lt;/strong&gt; since it was first created in 1997. Each conductor in each multiphase terminal has a built-in switch that may be opened or closed. Non-ideal switches of microohms upto milliohms may be added like any other branch if desired, but it is often not necessary. Relay, Recloser, and Fuse objects are Control elements that open and close terminals of some circuit element.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;OpenDSS does not use the &lt;strong&gt;per unit system&lt;/strong&gt; in its internal circuit model. All values are in actual volts, amperes, and Siemens. A nodal admittance circuit model is used because the Y matrix is sparse and the equation I = YV may be solved efficiently by readily-available sparse solvers. Input data and results may be reported in per unit values if the base voltages at the buses are defined.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;OpenDSS does not use &lt;strong&gt;symmetrical component&lt;/strong&gt; models in its solution. Values may be reported in positive, negative, and zero-sequence values if requested. Line impedances may be specified in symmetrical component values. This is frequently all that is available, although OpenDSS would prefer the unbalanced R, X, and C matrices (which it computes anyway).&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;For most passive elements in the power system, the positive- and negative-sequence impedances are equal (impedance matrices are symmetrical). Generators are the exception where the negative sequence impedance is generally less. Besides Generator models, the Vsource and Reactor models can handle this kind of model where the impedance matrix is anti-symmetrical.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;One concept that is different about OpenDSS is that there are&lt;strong&gt; no special buses.&lt;/strong&gt; Buses are simply collections of Nodes where conductors from the circuit elements are connected together. This is quite similar to the concept in EMT programs. Buses do not have to be pre-defined by the user. OpenDSS reads the bus names from the circuit element descriptions. In fact, bus objects are not actually instantiated until the first solution is performed.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;Network &lt;strong&gt;harmonics analysis&lt;/strong&gt; is a native capability of OpenDSS.  Loads, Generators, and PVSystems all have default harmonics spectrum object assigned.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;You can apply a &lt;strong&gt;Fault&lt;/strong&gt; during a power flow solution and a converged solution can generally be achieved.&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;OpenDSS has had &lt;strong&gt;Dynamics mode&lt;/strong&gt; solution capability (electromechanical transients) since 1997. The InductionMachine example provided with the program demonstrates this capability well, include protective device operation (multifunction Relay and a Recloser).&lt;/p&gt;
&lt;/li&gt;
&lt;/ol&gt;&lt;/div&gt;</summary></entry><entry><title>New Example Posted: Celso's Undergrad Project</title><link href="https://sourceforge.net/p/electricdss/news/2017/09/new-example-posted-celsos-undergrad-project/" rel="alternate"/><published>2017-09-12T12:40:32.554000Z</published><updated>2017-09-12T12:40:32.554000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.net564eee8bf41c65a68923e11086a5bd3b0ec67cfe</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;A frequent contributor to this forum, Celso Rocha, has graciously allowed us to post his undergrad project to the examples.  It has the DSS and Python files along with his report.  It should be a great help to users and we thank him.  You can find it at&lt;/p&gt;
&lt;p&gt;&lt;a href="https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Examples/Celso_Example"&gt;https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Examples/Celso_Example&lt;/a&gt;&lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>Portuguese Version of OpenDSS Primer Posted</title><link href="https://sourceforge.net/p/electricdss/news/2016/07/portuguese-version-of-opendss-primer-posted/" rel="alternate"/><published>2016-07-27T14:46:36.080000Z</published><updated>2016-07-27T14:46:36.080000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.netccb090dc2fe7afa13357f8d954faf698437f4c75</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;Here is the link:&lt;/p&gt;
&lt;p&gt;&lt;a href="https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/OpenDSSPrimer_Portuguese.pdf"&gt;https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/OpenDSSPrimer_Portuguese.pdf&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Thanks to Paulo and Celso&lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>Chinese versions of the OpenDSS Primer</title><link href="https://sourceforge.net/p/electricdss/news/2016/03/chinese-versions-of-the-opendss-primer/" rel="alternate"/><published>2016-03-18T13:31:24.572000Z</published><updated>2016-03-18T13:31:24.572000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.net24b2bed2f6d88f6dcd170c105f8ab1a74d1c4912</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;Huijuan Li has recently translated Jason Sexauer's  Primer for OpenDSS  into both Traditional and Simplified Chinese. You can find these documents here:&lt;/p&gt;
&lt;p&gt;&lt;a href="https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/OpenDSSPrimer_SimplifiedChinese.pdf"&gt;https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/OpenDSSPrimer_SimplifiedChinese.pdf&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/OpenDSSPrimer_TranditionalChinese.pdf"&gt;https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/OpenDSSPrimer_TranditionalChinese.pdf&lt;/a&gt;&lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>COM Interface -- Finding your way through all the properties</title><link href="https://sourceforge.net/p/electricdss/news/2016/03/com-interface----finding-your-way-through-all-the-properties/" rel="alternate"/><published>2016-03-18T13:26:20.465000Z</published><updated>2016-03-18T13:26:20.465000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.netd768d75e7365cb4144e676703d2d3b62837a90d5</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;Excel VBA is very good at prompting you for the OpenDSS COM interface properties and methods.  But if you are working in Python or MATLAB you may find it difficult to remember or figure out the property names.  Andrea Ballanti has put together a very nice TechNote on ways to see the list of properties in these languages as well:&lt;/p&gt;
&lt;p&gt;&lt;a href="https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/Technote_COM_PropertyListVisualization.pdf"&gt;https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/Technote_COM_PropertyListVisualization.pdf&lt;/a&gt;&lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>CN and TS Cable Modeling</title><link href="https://sourceforge.net/p/electricdss/news/2016/03/cn-and-ts-cable-modeling/" rel="alternate"/><published>2016-03-04T05:09:47.927000Z</published><updated>2016-03-04T05:09:47.927000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.net38244a763d4fef7264f9a73cfb9f42d0e71780b6</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;We've just posted a technote by Andrea Ballanti on how to model two types of underground cable in OpenDSS. Many users should find this useful as these models are not explained in the user's manual:&lt;br/&gt;
&lt;a href="https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/TechNote%20CableModelling.pdf"&gt;https://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Doc/TechNote%20CableModelling.pdf&lt;/a&gt;&lt;/p&gt;&lt;/div&gt;</summary></entry><entry><title>Example from Brazil Posted</title><link href="https://sourceforge.net/p/electricdss/news/2016/01/example-from-brazil-posted/" rel="alternate"/><published>2016-01-05T14:48:52.931000Z</published><updated>2016-01-05T14:48:52.931000Z</updated><author><name>Roger Dugan</name><uri>https://sourceforge.net/u/rdugan/</uri></author><id>https://sourceforge.neta2e1a2d41b7ad3a44cc18e009a6f51d2eafaaff7</id><summary type="html">&lt;div class="markdown_content"&gt;&lt;p&gt;There is a vibrant OpenDSS user community in Brazil.  Paulo Radatz, a student at the University of Sao Paulo, wrote a nice report for his undergraduate project and has contributed the DSS files from his project as a good example of how to use the program.&lt;br/&gt;
&lt;/p&gt;
&lt;p&gt;The report is in Portuguese, but is still understandable if you know the language of mathematics and OpenDSS script. &lt;/p&gt;
&lt;p&gt;You can find everything at:&lt;/p&gt;
&lt;p&gt;&lt;a href="http://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Examples/Paulo_Example"&gt;http://sourceforge.net/p/electricdss/code/HEAD/tree/trunk/Distrib/Examples/Paulo_Example&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Paulo interned in the Power Systems Studies group at EPRI in Knoxville, Tennessee during 2015 and has gained significant experience using the program. He has written Python programs that interact with OpenDSS and I expect future contributions will be coming soon.&lt;/p&gt;